Aircraft Fire and Rescue
•10,000 SF Structure
•800 Amp 208/120 Volt Service
•225 kva 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•200 kw Standby Generator with Automatic Transfer Switch
•PLC Wiring and Controls for PA, Roll-up Doors and Lighting
•Lightning Protection System
•Fire Alarm System with King Fisher Radio Transmitter
•PA/ Intercom Systems
•Interior/ Exterior Telecommunications System
•Mass Notification System
Hangar 414 Renovation, MCAS
•60,000 SF Structure
•2000 Amp 208/120 Volt Service
•1000 KVA 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•800 Amp 208/120 Volt Service
•300 KVA 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•Lightning Protection System
•Fire Alarm System
•PA/ Intercom Systems
•Interior/ Exterior Telecommunications System
Military Police/ Emergency Services Facility, MCRD
•12,000 SF Structure
•800 Amp 208/120 Volt Service
•300 KVA 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•400 KVA Standby Generator with Automatic Transfer Switch
•PLC Wiring and Controls for PA, Roll-up Doors and Lighting
•Lightning Protection System
•Fire Alarm System
•PA/ Intercom Systems
•Interior/ Exterior Telecommunications System
•New King Fisher Base Wide Reciever
Main Exchange, Parris Island
•60,000 SF Structure
•2000 Amp 208/120 Volt Service
•500 kva 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•100 kw Standby Generator with Automatic Transfer Switch
•Lightning Protection System
•Fire Alarm System
•PA/ Intercom Systems
•Interior/ Exterior Telecommunications System
•Mass Notification System
•Low Voltage Lighting Control System
Youth Center, Parris Island
•8,000 SF Structure
•400 Amp 208/120 Volt Service
•150 kva 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•Lightning Protection System
•Fire Alarm System with King Fisher Radio Transmitter
•PA/ Intercom Systems
•Interior/ Exterior Telecommunications System
•Mass Notification System
Temporary Barracks, Parris Island
•16 - 5,000 SF Modular Barracks
•1200 Amp 208/120 Volt 3 Phase Service for 4 seperate sites
•Underground Secondary for each site
•Lightning Protection System for each Barracks
•Fire Alarm System with King Fisher Radio Transmitter
•Interior Telecommunications System
Enlisted Dining Facility, MCAS
•13,000 SF Structure
•1200 Amp 208/120 Volt Service
•300 kva 12470/7200V Oil-Filled Padmount Transformer with Concrete Encased Underground Primary
•450 kw Standby Generator with Automatic Transfer Switch
•Lightning Protection System
•Fire Alarm System with King Fisher Radio Transmitter
•Interior/ Exterior Telecommunications System
•Mass Notification System